I have a JCL job to compile multiple Netview REXX execs for the Message Automation Table:
********************************* Top of Data ******************************
//REXXCOMP JOBCARD
//*--------------------------------------------------------------------
//*
//* BATCH REXX COMPILE
//*
//*--------------------------------------------------------------------
//REXXCOMP PROC
// EXEC REXXC,OPTIONS='XREF OBJECT'
//REXX.SYSIN DD DSN=SYSAOC.PRODNETV.EXECS(&MEMIN),DISP=SHR
//REXX.SYSCEXEC DD DSN=SYSAOC.PRODNETV.CEXEC(&MEMIN),DISP=SHR
// PEND
//*--------------------------------------------------------------------
//S01 EXEC REXXCOMP,MEMIN='MEMBER01'
//S02 EXEC REXXCOMP,MEMIN='MEMBER02'
//S03 EXEC REXXCOMP,MEMIN='MEMBER03'
//S04 EXEC REXXCOMP,MEMIN='MEMBER04'
//S05 EXEC REXXCOMP,MEMIN='MEMBER05'
//S06 EXEC REXXCOMP,MEMIN='MEMBER06'
//S07 EXEC REXXCOMP,MEMIN='MEMBER07'
//S08 EXEC REXXCOMP,MEMIN='MEMBER08'
//S09 EXEC REXXCOMP,MEMIN='MEMBER09'
//S10 EXEC REXXCOMP,MEMIN='MEMBER10'
I would like to create another PROC for this job to fire the NCCF MEMSTOUT command: MEMSTOUT &MEMIN
What's the ideal way to do this?
A timer, a route command, another REXX or JCL job?
EDIT:
Ideally I would like to add the following command to the PROC
MVS RO *ALL,%MEMSTOUT &MEMIN
Which at our shop routes to all LPARS the Netview command (%).
ie
//REXXCOMP PROC
// EXEC REXXC,OPTIONS='XREF OBJECT'
//REXX.SYSIN DD DSN=SYSAOC.PRODNETV.EXECS(&MEMIN),DISP=SHR
//REXX.SYSCEXEC DD DSN=SYSAOC.PRODNETV.CEXEC(&MEMIN),DISP=SHR
// COMMAND 'RO *ALL,%MEMSTOUT ''&MEMIN''
// PEND
I just do not know how to incorporate symbolic within the COMMAND. Keep getting JCL runtime error.